Product Features

  • VRLA (Valve Regulated Lead Acid) battery
  • Maintenance-free, using AGM (Absorbent Glass Mat) technology, with gas recombination efficiency up to 99%
  • Pure lead construction with proprietary element formulation
  • Designed for high-rate UPS and float charge backup power applications
  • Manufactured to IEC 61056-1/2:2012 standard, UL1989 certified (MH14533)

Application Scenarios

  • UPS system backup power for data centers
  • Uninterruptible power supply solutions for server rooms
  • Industrial-grade UPS high-power backup power applications
  • UPS emergency power for medical instruments
  • UPS backup protection for the financial sector
  • UPS backup power for telecom equipment rooms

Product parameters

  • Model:UPS122406
  • Voltage:12 Vdc
  • Nominal Capacity:240W @5min-rate
  • Watts per Cell:38.83 (5-Min 1.67 VPC @ 25°)
  • Watts per Cell:18.5 (15-Min 1.67 VPC @ 25°)
  • Max. Charge Current:2.00 A
  • Max. Discharge Current:130 A
  • Short Circuit Current:230 A
  • Internal Resistance:33.50 mΩ
  • Terminal Type:F2 terminal (Faston Tab 250)
  • Container Material:ABS (UL 94-HB) standard, flame-retardant (94-V0) available upon request
  • Weight:1.46 / 3.22 kg / lb.
  • Length (L):150.9±2.0 / 5.94±0.08 mm / in
  • Width (W):51.0±1.0 / 2.01±0.04 mm / in
  • Height (H):98.6±1.0 / 3.88±0.04 mm / in
  • Design Life:Up to 5 years in standby service at 25°C; Eurobat (20°C): 3-5 years, Standard Commercial
  • Float Charging Voltage:13.5 - 13.8 Vdc/battery
  • Equalizing Charging Voltage:14.4 - 15.0 Vdc/battery
  • Operating Temperature:discharge -15°C to 50°C; charge/storage -15°C to 40°C
  • Note:F1 terminal is available; Max Discharge Current = 100 A (5 sec.)

Product details

CSB UPS122406 is a member of the UPS series, a 6V and 12V top terminal Valve Regulated Sealed Lead Acid (VRLA) battery, utilizing Absorbent Glass Mat (AGM) technology, with gas recombination efficiency up to 99%, maintenance-free. The pure lead construction gives this series the characteristics to meet the high-rate discharge and float charge backup requirements of Uninterruptible Power Supply (UPS), with its official application pointing to data center UPS. Electrical parameters are as follows: UPS122406 rated voltage 12 Vdc, nominal capacity based on 9.60V per PCS @ 25°C condition, 240W @5min-rate. At 5 minutes 1.67 VPC @ 25°C, power per cell is 38.83 W/cell, at 15 minutes 1.67 VPC @ 25°C, it is 18.5 W/cell. Maximum charge current 2.00 A, maximum discharge current 130 A, short circuit current 230 A, internal resistance 33.50 mΩ. Float charge voltage 13.5 to 13.8 Vdc/battery (25°C), equalize charge voltage 14.4 to 15.0 Vdc/battery (25°C). Terminal adopts F2 terminal - Faston Tab 250. Case is ABS (UL 94-HB) material, flame retardant (94-V0) version available upon request. Dimensions: length 150.9±2.0 mm, width 51.0±1.0 mm, height 98.6±1.0 mm, weight approximately 1.46 kg. Design life 5 years under 25°C float charge standby service, Eurobat (20°C) standard commercial is 3 to 5 years. Operating temperature: nominal 25°C (77°F), discharge -15°C to 50°C (5°F to 122°F), charge and storage -15°C to 40°C (5°F to 104°F). Self-discharge: less than 10% self-discharge when stored at 25°C (77°F) for 90 days, can be stored for up to 6 months; must be fully charged before use, and if storage temperature is above 25°C (77°F), charge in advance. The product complies with IEC 61056-1/2:2012 standard, recognized by UL1989 (MH14533). With these features, it is suitable for applications requiring high-rate discharge and float charge backup such as data center UPS.