Product Features

  • Uses Valve Regulated Lead Acid (VRLA) technology
  • Absorbent Glass Mat (AGM) design, maintenance-free, with gas recombination efficiency up to 99%
  • Equipped with pure lead plates and proprietary element formula
  • Suitable for high-rate UPS and float charge backup power applications
  • Manufactured to IEC 61056-1/2:2012 standards, UL1989 certified (MH14533)

Application Scenarios

  • Data center UPS backup battery
  • Server room UPS backup power
  • Industrial high-power UPS backup
  • Medical equipment emergency UPS power
  • Financial system UPS backup
  • Telecom room UPS backup battery

Product parameters

  • Model:UPS12460
  • Voltage:12 Vdc
  • Nominal Capacity:460W @5min-rate
  • Watts per Cell:74.00 (5-Min 1.67 VPC @ 25°)
  • Watts per Cell:36.83 (15-Min 1.67 VPC @ 25°)
  • Max. Charge Current:3.80 A
  • Max. Discharge Current:130 A
  • Short Circuit Current:450 A
  • Internal Resistance:16.60 mΩ
  • Terminal Type:F2 terminal (Faston Tab 250)
  • Container Material:ABS (UL 94-HB) standard, flame-retardant (94-V0) available upon request
  • Weight:2.50 / 5.51 kg / lb.
  • Length (L):150.9±2.0 / 5.94±0.08 mm / in
  • Width (W):64.8±1.0 / 2.55±0.04 mm / in
  • Height (H):98.6±1.0 / 3.88±0.04 mm / in
  • Design Life:Up to 5 years in standby service at 25°C; Eurobat (20°C): 3-5 years, Standard Commercial
  • Float Charging Voltage:13.5 - 13.8 Vdc/battery
  • Equalizing Charging Voltage:14.4 - 15.0 Vdc/battery
  • Operating Temperature:discharge -15°C to 50°C; charge/storage -15°C to 40°C

Product details

The CSB UPS12460 belongs to the UPS series, whose product types cover 6V and 12V top terminal VRLA-AGM batteries, with official application in data center uninterruptible power supplies. The series is positioned as a high-power pure lead UPS battery series for uninterruptible power supply applications. For this specific model, the nominal voltage is 12 Vdc, and the nominal capacity is 460W at the 5-minute rate at 9.60V per PCS @ 25°C; the per-cell power is 74.00 W/cell at 25°C, 1.67 VPC, 5 minutes, and 36.83 W/cell at 25°C, 1.67 VPC, 15 minutes. Electrically, the UPS12460 has a maximum charge current of 3.80 A, a maximum discharge current of 130 A, a short-circuit current of 450 A, and an internal resistance of 16.60 mΩ. The float charge voltage is 13.5 to 13.8 Vdc/battery (25°C), and the equalization charge voltage is 14.4 to 15.0 Vdc/battery (25°C). Regarding self-discharge, capacity loss after 90 days of storage at 25°C is less than 10%, and storage is possible for up to 6 months, with a full charge required before use; if the storage temperature exceeds 25°C, an earlier charge is required. The battery's structural features include a valve regulated sealed lead acid design and Absorbent Glass Mat technology, with a gas recombination efficiency of up to 99%, and it uses pure lead construction with proprietary elements. The case material is ABS (UL 94-HB), and a flame-retardant version (94-V0) is available on request. The terminal type is F2 terminal - Faston Tab 250. Dimensions: length 150.9±2.0 mm, width 64.8±1.0 mm, height 98.6±1.0 mm, weight 2.50 kg. In terms of temperature and life, the nominal operating temperature is 25°C, the discharge temperature range is -15°C to 50°C, and the charge and storage temperature range is -15°C to 40°C. The design life is up to 5 years in float charge standby service at 25°C, and 3 to 5 years for standard commercial applications per Eurobat (20°C). The product is manufactured in accordance with IEC 61056-1/2:2012 and is recognized under UL1989 (MH14533). Based on the above characteristics, the UPS12460 is suitable for float charge standby scenarios in data center uninterruptible power supplies, with a design focused on high-rate discharge and maintenance-free operation, meeting the requirements of standby power applications in float charge service for battery consistency, sealing, and gas recombination.