Product Features

  • Valve Regulated Lead Acid (VRLA) technology
  • Absorbent Glass Mat (AGM) design, maintenance-free, with up to 99% gas recombination efficiency
  • Pure lead construction with proprietary element formulation
  • Developed primarily for float charge backup power applications
  • Manufactured to IEC 61056-1/2:2012 standards, also UL1989 certified (MH14533)

Application Scenarios

  • Backup power for security alarm panels
  • Emergency lighting and evacuation indication devices
  • Backup power for medical monitors and infusion pumps
  • Access control systems and building intercom equipment
  • Fire alarm and linkage control panels
  • Small electronic instruments and testing equipment

Product parameters

  • Model:GP1245 12V16W
  • Voltage:12 Vdc
  • Nominal Capacity:16W @15Min-rate
  • Watts per Cell:34.8 (5-Min 1.67 VPC @ 25°)
  • Watts per Cell:16.4 (15-Min 1.67 VPC @ 25°)
  • Max. Charge Current:1.60 A
  • Max. Discharge Current:90 A
  • Short Circuit Current:168 A
  • Internal Resistance:29.8 mΩ
  • Terminal Type:F2 terminal (Faston Tab 250)
  • Container Material:ABS (UL 94-HB) standard, flame-retardant (94-V0) available upon request
  • Weight:1.34 / 2.95 kg / lb.
  • Length (L):90.0±1.0 / 3.54±0.04 mm / in
  • Width (W):70.0±1.0 / 2.76±0.04 mm / in
  • Height (H):106.1±1.5 / 4.18±0.06 mm / in
  • Design Life:Up to 5 years in standby service at 25°C; Eurobat (20°C): 3-5 years, Standard Commercial
  • Float Charging Voltage:13.5 - 13.8 Vdc/battery
  • Equalizing Charging Voltage:14.4 - 15.0 Vdc/battery
  • Operating Temperature:discharge -15°C to 50°C; charge/storage -15°C to 40°C
  • Note:F1 terminal is available; Max Discharge Current = 60 A

Product details

The GP1245 is a general purpose Valve Regulated Sealed Lead Acid battery in the CSB GP series, with a nominal voltage of 12 Vdc and a nominal capacity of 16W at the 15-minute rate (1.67 VPC @25°C). This battery utilizes Absorbent Glass Mat (AGM) technology, achieves a gas recombination efficiency of 99%, features a maintenance-free design, and is suitable for float charge backup power. In terms of electrical parameters, the GP1245 delivers 34.8 W/cell at the 5-minute rate (1.67 VPC @25°C) and 16.4 W/cell at the 15-minute rate. The maximum charge current is 1.60 A, the maximum discharge current is 90 A, the short-circuit current is 168 A, and the internal resistance is 29.8 mΩ. The float charge voltage should be maintained at 13.5 - 13.8 Vdc/battery (25°C), and the equalization charge voltage is 14.4 - 15.0 Vdc/battery (25°C). In terms of dimensions, the battery is 90.0±1.0 mm long, 70.0±1.0 mm wide, and 106.1±1.5 mm high, with a weight of approximately 1.34 kg. The terminal type is F2 terminal - Faston Tab 250. The case is made of ABS material (UL 94-HB), and a flame-retardant (94-V0) version is also available upon request. Operating temperature range: nominal 25°C; -15°C to 50°C during discharge; -15°C to 40°C during charge/storage. Under float charge conditions at 25°C, the design life can reach 5 years, meeting the Eurobat (20°C) 3-5 year standard commercial grade requirement. The self-discharge rate is low, less than 10% after 90 days, and it can be stored at 25°C for up to 6 months. It must be fully charged before use, and if the storage temperature exceeds 25°C, it should be charged earlier. This battery is manufactured in accordance with the IEC 61056-1/2:2012 standard and is recognized by UL1989 (MH14533). The official application area is general purpose, suitable for scenarios such as security, emergency lighting, and medical equipment.